Technical Specifications

Model
RT-5K / RT-6K / RT-10K
Power Rating
[5K]: 5kVA/4.5kW
 
[6K]: 6kVA/5.4kW
 
[10K]: 10kVA/9kW
Input
 
Nominal Voltage
200/208/220/230/240 Vac (single phase)
Voltage Range
100~300Vac *
Current Harmonic Distortion
< 5% (full load)
Power Factor
> 0.99 (full load)
Frequency
40 ~ 70 Hz
Electrical Connection
Terminal block
Output
 
Voltage
200/208/220/230(default)/240 Vac (single phase)
Voltage Harmonic Distortion
< 2% (linear load)
Voltage Regulation
± 1% (static)
 
± 2% (typical)
Frequency
50 or 60 ± 0.05 Hz
Overload Capability
106 ~ 110%: 10 minutes
 
111 ~ 125%: 5 minutes
 
126 ~ 150%: 30 seconds
Electrical Connection
Terminal block
Crest Factor
3:1
Battery & Charger
 
Nominal Voltage
[5K]: 192 Vdc
 
[6K]: 192 Vdc
 
[10K]: 240 Vdc
Charge Current
Built-in: maximum 4A (adjustable)
 
Additional charger board (optional): maximum 4A (internal installation)
Electrical Connection
Exclusive cable
Interface
 
Standard
RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
Conformance
 
Safety & EMC
CE, TUV, EN62040-1
 
CISPR 22 Class A
Others Features
 
Parallel Redundancy
1+1
Remote Control
REPO, Remote On/Off
Common Battery Installation
Yes
Efficiency
 
AC-AC
92% (full load)
ECO Mode
96% (full load)
Environment
 
Operating Temperature
0 ~ 40ºC
Relative Humidity
0 ~ 95% (non-condensing)
Audible Noise(at one meter)
54 dBA **
Physical
 
UPS Dimensions(WxDxH)
[5K]: 440 x 671 x 89 mm
 
[6K]: 440 x 671 x 89 mm
 
[10K]: 440 x 623 x 131 mm
Battery Pack Dimensions(WxDxH)
[5K]: 440 x 638 x 89 mm
 
[6K]: 440 x 638 x 89 mm
 
[10K]: 440 x 595 x 131 mm
UPS Weight
[5K]: 15 kg
 
[6K]: 15.5 kg
 
[10K]: 21.3 kg
Battery Pack Weight
[5K]: 36 kg
 
[6K]: 36 kg
 
[10K]: 66 kg
* For 5 and 6 kVA models, lower range 100 ~ 155 Vac is acceptable under 50 ~ 100% loading condition.
   For 10 kVA model, lower range 100 ~ 180 Vac is acceptable under 50 ~ 100% loading condition.
** Audible Noise is at 70% load.

All specifications are subject to change without prior notice.